Aux 2 Unit 5 Q2

  1. With reference to a solid state (inverter) starter for a 3 phase induction motor:
    (a) explain the starting characteristics of this system;4)
    (b) list the advantages and disadvantages when compared to conventional starting methods.(6)

What is a solid state (inverter) starter for a 3 phase induction motor?

A solid-state (inverter) starter for a 3-phase induction motor, often referred to as a soft starter, is a device used to control the motor’s starting current and torque. It utilizes solid-state power electronics, such as thyristors or silicon-controlled rectifiers (SCRs), to gradually ramp up the voltage applied to the motor during startup, thereby reducing the inrush current and mechanical stress on the motor and driven equipment.  

Key Features:

  • Reduced Voltage Starting: Solid-state starters achieve reduced voltage starting by controlling the firing angle of the SCRs, which effectively chops the incoming voltage waveform and delivers a lower average voltage to the motor during the starting phase.  
  • Smooth Acceleration: They provide smooth and controlled acceleration, minimizing mechanical shock and stress on the motor and connected machinery.  
  • Adjustable Starting Parameters: Various starting parameters, such as ramp-up time, initial voltage, and current limit, can be adjusted to suit the specific application and load requirements.  
  • Soft Stopping: Some solid-state starters also offer soft stopping capabilities, gradually reducing the voltage and frequency to achieve a controlled deceleration of the motor.  

Advantages:

  • Reduced Inrush Current: Significantly reduces the high inrush current associated with direct-on-line (DOL) starting, minimizing the impact on the power supply and preventing voltage dips.  
  • Smooth Starting and Stopping: Provides smooth and controlled acceleration and deceleration, reducing mechanical stress on the motor and driven equipment.  
  • Adjustable Starting Characteristics: Allows for customization of starting parameters to match specific load requirements.  
  • Energy Savings: Can reduce energy consumption during starting compared to other starting methods.  
  • Improved Power Factor: Can help improve the power factor of the system during starting.  

Disadvantages:

  • Higher Cost: Compared to traditional electromechanical starters like star-delta starters, solid-state starters are generally more expensive.
  • Complexity: They are more complex than traditional starters, requiring specialized knowledge for installation, setup, and troubleshooting.
  • Heat Dissipation: They generate heat during operation, necessitating adequate cooling arrangements.
  • Harmonics: They can introduce harmonics into the power supply, which may require additional filtering to prevent interference with other equipment.

Applications:

  • Pumps, Fans, and Compressors: Commonly used in applications where high starting torque is not required and smooth acceleration is desired.
  • Conveyors and Cranes: Suitable for applications where mechanical shock and stress on the driven equipment need to be minimized.  
  • Other Industrial Applications: Used in various industrial settings where reduced starting current, smooth starting, and controlled acceleration are beneficial.  

Comparison with VFDs:

  • While both solid-state starters and VFDs use power electronics to control motor starting, VFDs offer a wider range of speed control and more advanced features like torque control and energy saving.
  • Solid-state starters are typically simpler and more cost-effective than VFDs, making them suitable for applications where only starting control is required.  

In conclusion, solid-state (inverter) starters are a valuable tool for controlling the starting of three-phase induction motors. They offer advantages in terms of reduced starting current, smooth acceleration, and energy savings. However, they are generally more expensive and complex than traditional starters and may not be suitable for all applications.

Starting characteristics of this system

Solid-state (inverter) starters, also known as soft starters, provide several distinct starting characteristics that differentiate them from traditional starting methods like Direct On Line (DOL) or Star-Delta starters. Let’s break down these characteristics:

  1. Reduced Starting Current:
  • Controlled Voltage Ramp-Up: The core principle of a soft starter is to gradually increase the voltage applied to the motor during startup. This controlled ramp-up significantly reduces the inrush current compared to DOL starting, where the motor is subjected to full voltage instantaneously.
  • Current Limiting: Many soft starters also have built-in current limiting features, further ensuring that the starting current stays within safe and acceptable limits, protecting both the motor and the electrical system.
  1. Smooth Acceleration:
  • Controlled Torque: By gradually increasing the voltage, soft starters provide a smooth and controlled acceleration of the motor. This minimizes mechanical shock and stress on the motor, its bearings, and the connected equipment, leading to longer equipment life and reduced maintenance costs.
  • Reduced Mechanical Stress: The smooth acceleration also helps prevent sudden torque spikes that could damage couplings, belts, or other transmission components.
  1. Adjustable Starting Parameters:
  • Ramp-Up Time: The ramp-up time, or the duration over which the voltage is gradually increased, can be adjusted to match the specific load requirements. This allows for optimizing the starting process based on the inertia and torque characteristics of the driven equipment.
  • Initial Voltage: The initial voltage applied to the motor can also be adjusted, further customizing the starting behavior and limiting the inrush current.
  • Current Limit: Some soft starters allow for setting a maximum current limit during startup, providing an additional layer of protection against excessive current draw.
  1. Soft Stopping (Optional):
  • Controlled Deceleration: Many soft starters also offer soft stopping capabilities, gradually reducing the voltage and frequency to achieve a controlled deceleration of the motor. This can be particularly beneficial in applications where sudden stops could cause damage or instability.
  1. Other Benefits:
  • Improved Power Factor: Soft starters can help improve the power factor during startup by reducing the reactive current component.
  • Reduced Voltage Sags: By limiting the inrush current, they minimize voltage sags on the power supply, preventing disruptions to other equipment on the same network.
  • Diagnostics and Protection: Many soft starters incorporate diagnostic and protection features, such as monitoring for motor overloads, phase imbalances, or ground faults, enhancing the overall safety and reliability of the system.

In summary, the starting characteristics of a solid-state (inverter) starter are characterized by reduced starting current, smooth acceleration, and adjustable starting parameters. These features offer significant advantages in terms of protecting the motor and electrical system, reducing mechanical stress, and improving overall operational efficiency.

Advantages and disadvantages when compared to conventional starting methods.

Advantages of Solid-State (Inverter) Starters over Conventional Starting Methods:

  • Reduced Starting Current and Voltage Sags: Soft starters significantly reduce the inrush current compared to Direct On Line (DOL) starting, minimizing stress on the electrical system and preventing voltage dips that can affect other equipment.
  • Smooth and Controlled Acceleration: They provide gradual voltage ramp-up and controlled acceleration, reducing mechanical stress on the motor and driven equipment, leading to longer lifespan and reduced maintenance.
  • Adjustable Starting Parameters: Allow customization of starting parameters like ramp-up time and initial voltage to match the specific load requirements, optimizing the starting process and minimizing energy consumption.
  • Soft Stopping: Many soft starters offer controlled deceleration, reducing mechanical stress during stopping and improving process control.
  • Energy Savings: Can provide energy savings during starting compared to other reduced voltage starting methods like star-delta starters.
  • Improved Power Factor: Helps improve the power factor during startup by reducing the reactive current component.
  • Diagnostics and Protection: Often include built-in diagnostics and protection features for monitoring motor health and preventing damage due to overloads, phase imbalances, or other faults.

Disadvantages of Solid-State Starters compared to Conventional Methods:

  • Higher Cost: Soft starters are generally more expensive than traditional electromechanical starters like DOL or star-delta starters.
  • Complexity: They are more complex, requiring specialized knowledge for installation, setup, and troubleshooting.
  • Heat Dissipation: They generate heat during operation, necessitating proper cooling arrangements.
  • Harmonics: Can introduce harmonics into the power supply, which may require additional filtering to avoid interference with other equipment.
  • Limited Speed Control: While providing excellent control during starting and stopping, they do not offer continuous speed control like Variable Frequency Drives (VFDs).

Comparison with Conventional Methods:

  • DOL Starting:
    • Simplest and cheapest method.
    • High inrush current and torque, causing stress on the system and potential voltage dips.
    • Not suitable for applications with sensitive equipment or high inertia loads.
  • Star-Delta Starting:
    • Reduces starting current and torque compared to DOL.
    • Less expensive than soft starters but still requires additional contactors and control circuitry.
    • Causes a transient torque dip during the transition from star to delta, which can be problematic for some applications.
    • Offers no control over acceleration or deceleration.
  • Autotransformer Starting:
    • Provides reduced voltage starting with higher starting torque than star-delta.
    • More complex and expensive than star-delta starters.
    • Still causes a step change in voltage during transition, leading to some mechanical stress.

Overall, solid-state starters offer a good balance between cost and performance, providing significant advantages over DOL starting in terms of reduced starting current and smooth acceleration. While they are more expensive than traditional electromechanical starters, their benefits in terms of energy savings, equipment protection, and improved control can justify the investment in many applications.

However, if continuous speed control or very high starting torque is required, a VFD might be a more suitable choice despite its higher cost and complexity.