Aux 2 Unit 7 Load sharing Quiz

3

Aux 2 Unit 7 Q1

1 / 7

If the excitation of one generator in a parallel system decreases, how does this affect the load sharing between the generators?

2 / 7

What can be the effect on the mechanical parts of the generators if they are connected out of phase?

3 / 7

What electrical phenomenon can occur if the main circuit breaker is closed while the generators are out of phase?

4 / 7

What happens to the reactive power output of one generator if its excitation is reduced while the load on the system remains constant?

5 / 7

Why is it critical to ensure that the phases of two generators are in phase before closing the main circuit breaker?

6 / 7

What is a potential effect on the system if one generator’s excitation is reduced significantly while operating in parallel?

7 / 7

What is the potential consequence of closing the main circuit breaker when the frequency and voltage are equal, but the phases are out of phase?

3

Aux 2 Unit 7 Q2

1 / 6

What can occur if generators with different speed droop settings are running in parallel and the load suddenly increases?

2 / 6

What effect would unequal droop settings have on frequency when generators are sharing an increasing load?

3 / 6

What is the term "speed droop" in relation to an AC generator?

4 / 6

Why is speed droop important in the operation of AC generators in parallel?

5 / 6

How does speed droop help maintain load sharing stability between parallel generators?

6 / 6

What happens when two generators with different speed droop settings are running in parallel and are sharing the load equally?

3

Aux 2 Unit 7 Q3

1 / 7

What is a potential risk if one generator’s AVR fails to provide sufficient output while running in parallel?

2 / 7

Why is it essential for an AVR to maintain a stable voltage output?

3 / 7

What is the primary purpose of an Automatic Voltage Regulator (AVR) in an AC generator?

4 / 7

What would be the immediate effect if one generator’s AVR gives a low output while running in parallel with a second generator whose AVR is functioning correctly?

5 / 7

What impact could a low output from an AVR have on connected equipment when a generator is running on its own?

6 / 7

What would be the observed effect if an AVR gives a low output when a generator is running independently?

7 / 7

How does a generator with a low AVR output affect the other generator when running in parallel?

2

Aux 2 Unit 7 Q4

1 / 8

Which of the following is a primary component of a diesel generator's electronic governor?

2 / 8

What happens when the electronic governor detects an increase in load on the generator?

3 / 8

What component in an electronic governor receives feedback from the speed sensor to adjust the fuel supply?

4 / 8

Which part of the electronic governor is responsible for making physical adjustments to the fuel supply in a diesel generator?

5 / 8

Why is load sensing important in the operation of an electronic governor for a diesel generator?

6 / 8

What happens if the speed sensor in an electronic governor fails?

7 / 8

What is the primary purpose of the electronic governor in a diesel generator?

8 / 8

How does an electronic governor maintain the speed of a diesel generator?