Aux 1 Unit 12 Trips, Alarms, Fuses Quiz

8

Aux 1 Unit 12 Q1

1 / 10

What does discrimination refer to in the context of electrical protection systems?

2 / 10

Which of the following best describes a non-essential consumer in an electrical system?

3 / 10

In which situation would preferential tripping most likely be activated?

4 / 10

Why is it important to identify and manage non-essential consumers in an electrical system?

5 / 10

What is the purpose of sequential starting in an electrical system?

6 / 10

When is sequential starting most likely to be used in an electrical system?

7 / 10

In what scenario is fuse back up protection most critical?

8 / 10

What is fuse back up protection designed to do in an electrical system?

9 / 10

What is the primary purpose of preferential tripping in an electrical system?

10 / 10

Why is discrimination important in an electrical system?

2

Aux 1 Unit 12 Q2

1 / 10

What is the purpose of testing the generator over-current alarm?

2 / 10

What is the most common method to test a generator reverse power trip for correct operation?

3 / 10

How can the preferential tripping sequence be tested?

4 / 10

Why is testing the preferential tripping sequence important?

5 / 10

What is the procedure to test the auto start-up of an emergency generator?

6 / 10

What is the correct procedure for testing a generator over-current trip?

7 / 10

How can a generator over-current alarm be tested for proper operation?

8 / 10

Why is it critical to test the generator over-current trip?

9 / 10

Why is it important to test the generator reverse power trip?

10 / 10

Why is it important to test the emergency generator's auto start-up feature?

3

Aux 1 Unit 12 Q3

1 / 10

What final step should be taken once alignment is completed and verified?

2 / 10

Which tool is commonly used to check the initial rough alignment between the motor and the pump?

3 / 10

Why is it important to check for any potential soft foot condition before operating the pump?

4 / 10

What is a common method for correcting vertical misalignment during motor and pump alignment?

5 / 10

What additional check should be made regarding the coupling before using the pump after alignment?

6 / 10

What is one of the critical checks to perform before operating the pump after the motor alignment is completed?

7 / 10

How is horizontal misalignment corrected during motor and pump alignment?

8 / 10

After the initial rough alignment, what method is typically used for fine alignment?

9 / 10

What is the first step in aligning a new motor with an existing pump?

10 / 10

Why is it important to rotate the shafts and recheck alignment at various points during the process?

1

Aux 1 Unit 12 Q4

1 / 10

What additional consideration must be made when mounting a thrust block on a bedplate in a ship's hull?

2 / 10

What is the role of the bedplate in the mounting arrangement of a thrust block?

3 / 10

Why is it important to maintain the correct clearance between the thrust block pads and the collar?

4 / 10

What component of the propulsion system directly transmits the propeller thrust to the thrust block?

5 / 10

What is a common mounting arrangement for a thrust block to the hull?

6 / 10

Why is it important for the thrust block to be securely mounted to the hull?

7 / 10

What is the potential consequence of having too much clearance between the thrust block pads and the collar?

8 / 10

Why are flexible mounts or shock absorbers used in the thrust block mounting arrangement?

9 / 10

How is the thrust generated by a propeller transmitted to a vessel's hull?

10 / 10

What could happen if the clearance between the thrust block pads and the collar is too tight?

2

Aux 1 Unit 12 Q5

1 / 10

What could happen if the preferential trip mechanism fails to operate during an overload condition?

2 / 10

During an overload situation, what is the first action taken by the preferential trip mechanism?

3 / 10

Which of the following is an example of a circuit that should not be connected to a preferential trip?

4 / 10

How does a preferential trip determine which circuits to disconnect during an overload?

5 / 10

What is the primary purpose of a preferential trip in an electrical system?

6 / 10

Why is it important that propulsion control circuits are not connected to a preferential trip?

7 / 10

Which of the following circuits should be prioritized to remain operational and therefore not be connected to a preferential trip?

8 / 10

Which type of circuits cannot be connected to a preferential trip?

9 / 10

In what scenario would a preferential trip typically be activated?

10 / 10

Which of the following types of circuits are generally not affected by preferential tripping to ensure continuous operation?